Vicon part number 8009-8134-08-01 Section 3 Rev 209 XX134-08-01 Camera Dome
Table 1 Models and Descriptions Model Number Product Code Environment/ Cable Type Camera Type/Format Mount Type Optical Zoom/ Total Zoom Lower Dome
Power Table Power* (W) Current Rating (A) Model Number Coax, UTP, Fiber ViconNet Coax, UTP, Fiber ViconNet SVFT-C22/ SVFT-C22C 24 34 1.0 1.4 SVF
How to Use this Manual This manual was designed to provide the best overall instructions for the installation and operation of the SurveyorVFT Camera
Accessory Kits There are 3 different accessory kits included with the different configurations of SurveyorVFT; Standard/Fiber-Optic Option, Twisted P
Unpacking the SurveyorVFT In-Ceiling Unpacking the SurveyorVFT Indoor Pendant 6 • 3BIntroduction XX134-08-01 Rev 209 SurveyorVFT Camera Dome
Unpacking the SurveyorVFT Outdoor Pendant XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 3BIntroduction • 7
SurveyorVFT Components All SurveyorVFT units are comprised of an Enclosure/Housing, a Camera Drive, a Shroud and a Lower Dome. Figures 1, 2 and 3 sho
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 3BIntroduction • 9 Figure 3 SurveyorVFT Outdoor Pendant Figure 2 SurveyorVFT Indoor Pendant
10 • 3BIntroduction XX134-08-01 Rev 209 SurveyorVFT Camera Dome System
Installation Choose the installation type based on the specific unit purchased (In-Ceiling, Indoor or Outdoor Pendant). Quick Installation – In-Ceili
Quick Installation – Indoor Pendant Q U I C K I N S T A L L A T I O N QUICKINSTALLATION 12 • 4BInstallation XX134-08-01 Rev 209 SurveyorVF
Quick Installation – Outdoor Pendant QUICKINSTALLATION Q U I C K I N S T A L L A T I O N XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 4
Detailed Installation These steps provide the most thorough and accurate instructions. In-Ceiling Mount Model This version of SurveyorVFT mounts in t
The accessory kit contains the removable screw terminal blocks to be used for all connections in this installation. Figure 6 Unlatching the Custome
Note: There should be minimal wire slack at all connection points. a) Strip approximately 1 inch (25 mm) of cable outer jacket to be terminated in
9. Connect the enclosure’s safety cord clip to the tab in the camera drive to allow the drive to hang from the enclosure. Refer to Figure 7 for loc
Optional Independent Support If it is necessary to provide independent support for the SurveyorVFT, other than the ceiling material, order the optio
Indoor Pendant Model The indoor pendant model mounts on a Vicon mount (refer to the table in the Introduction section) or a 1.5-inch vertical pipe w
Figure 12 Unlatching the Customer Interface Board b) Refer to Wiring section and Tables 2A, 2B and 2C to make all connections to terminal block TB
Figure 13 Safety Cord Installation 12. Lift the SurveyorVFT camera drive up to the housing and attach the housing’s safety cord clip to the camer
Important Safeguards – Outdoor Use GRAPHIC SYMBOL EXPLANATION The lightening bolt symbol alerts the user to the presence of dangerous voltage that ma
Outdoor Pendant Model The Outdoor Pendant model mounts on a Vicon mount (refer to the table in the Introduction section) or a 1.5-inch vertical pip
Alternate Mounting Configuration b) Refer to Wiring section and Table 2 to make all connections to terminal block TB1 (power), TB2 (alarms), TB3
13. Install the provided optional heater duct (recommended to minimize condensation problems). It is used to redirect warm air onto the lower dome s
15. Align the tabs on the camera drive with the slots in the housing, matching up the two arrows on the camera drive and the housing. Figure 17 In
Figure 18 Outdoor Lower Dome Installation 26 • 4BInstallation XX134-08-01 Rev 209 SurveyorVFT Camera Dome System
Wiring Wiring is done with runs of cable for power, video and control. Optional wiring can be installed for the relay output and alarm inputs. All ca
Figure 19 Customer Interface Board Connections 28 • 5BWiring XX134-08-01 Rev 209 SurveyorVFT Camera Dome System
Typical Relay and Alarm Connections Alarm input and relay output type signals are also carried on individually-shielded twisted-pair cable sets. The
Installing the Cables WARNING: Disable the AC power to prevent installer injury and damage to the unit. Cables are installed using 2 different metho
For an Indoor or Outdoor Pendant Model Installation Refer to Figure 19 customer interface boards for indoor or outdoor pendant model mount cable ins
CONNECTOR/PIN NUMBERCONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAMEBNC (female)VIDEO (J1)J1VIDEOVideo outputAMP HeaderJ2J2 (Fiber Optic board)* Video/
CONNECTOR/PIN NUMBERCONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAMETERMINAL BLOCKVIDEO NVT (TB4)TB4-1UTP +Unshielded twisted pair +TB4-2UTP -Unshielde
CONNECTOR/PIN NUMBERCONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAMETERMINAL BLOCKPOWER (TB1)TB1-1HHotTB1-2NNeutralTERMINAL BLOCKALARM (TB2)TB2-1ALARM
Installation Configurations There are two types of installation configurations for coaxial, twisted-pair and fiber-optic domes, daisy-chain or star,
Installing the Flash Upgrade and PC Direct Control It is possible to upgrade software for the SurveyorVFT through a PC and to control the SurveyorVFT
Standalone Configuration System Star Configuration When multiple domes are connected in a star configuration, using a V1400X-IDL, the RS-232/RS-42
Star Configuration System After the physical connections are made, insert the software disk and select the appropriate program, Flash Upgrade Util
Configuration The SurveyorVFT must be configured for its address and mode and termination setting when using RS-422/RS-485 protocol. The address and
NOTE: DIP switches labeled ON or CLOSED and OFF or OPEN have the same meaning. Figure 23 DIP Switch Label Competitive Protocol Settings, SW2 Swi
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 6BConfiguration • 41 DIP Switch 1 (SW1) Address (Pilot/NOVA/VPS Mode) SWITCHES SWITCHES SWITCH
FCC Notice Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device. WARNIN
Setting the End-of-Line Jumpers JP1, JP2 & JP3 for RS-485 Protocol Operation Figure 24 End-of-Line Jumper Location This section defines settin
When adding a SurveyorVFT IP Camera to the ViconNet network, the following items must be considered: • The number of cameras on a switch with respe
Setup TAB Note: Since the Setup configuration affects the entire installation process, it MUST be configured first. In the Setup TAB, 3 fields are d
4. Press the Select button on the lower section of the screen. Note: You MUST click the Select button to add the unit to the list; verify that it is
Install TAB The Install TAB allows the user to install/upgrade newer versions. Choose the correct version and click Install to send to the selected u
Advanced TAB The Advanced TAB functionalities allow the user to handle unexpected events on a specific remote unit when they occur. When a problem o
Custom TAB The Custom TAB allows setup of the VOX settings. The VOX mechanism allows setting the IP device so that it will not transmit audio if the
After the SurveyorVFT has been configured for ViconNet, upon another boot up (or preset 97), the opening screen will display (see below). This screen
ViconNet Configuration After the camera dome has been setup with the proper IP address, configuration features from a remote workstation, server or r
Uninstalling the SurveyorVFT The SurveyorVFT camera drive can be easily uninstalled by simply pushing in the tabs to release the camera drive from th
Operation Following the complete installation and setup of the SurveyorVFT, it is necessary to perform initial power-up testing and verify proper ope
Verifying Proper Operation Set up a remote keypad via RS-422/485 or a Pilot/NOVA/VPS CPU via RS-422/485 or Vicoax protocol to the SurveyorVFT. Power-
54 • 8BOperation XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 2. Press the PP ENTER key; the PRESET LED displays a blinking 0. 3. Press
Competitive Protocols The SurveyorVFT Camera Dome can be operated by a number of competitive protocols. The tables below outline how to use the funct
Pelco Function Keypress Function KeypressEnter Menu95, Preset Set (Program Label screen appears), F2 Set Transmit Polarity93, Preset Set (Program La
Sensormatic Function Keypress Function KeypressEnter MenuPress and hold IRIS Open, press and hold Focus (near or far), press Zoom OutSet Transmit Po
Kalatel Function Keypress Function KeypressEnter MenuPress Set until "Enter Programming Code" appears. Enter Access Code 951followed by SE
Ultrak When changing SurveyorVFT software addresses, the keypad may not respond to all 256 addresses. The workaround is to go to Ultrak KEGS Setup
60 • 9BCompetitive Protocols XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Panasonic Function Keypress Function KeypressEnter MenuPress and
Philips Function Keypress Function KeypressEnter MenuUse On-46-Enter shortcut to enter Dome menu. Use Focus Far button to select and save options. U
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System • iii Contents INTRODUCTION...
62 • 9BCompetitive Protocols XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Cohu Function Keypress Function KeypressEnter MenuTo launch Dome
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 10BMaintenance • 63 Maintenance The SurveyorVFT requires no scheduled maintenance; however, the
64 • 11BShipping Instructions XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Shipping Instructions e FarehamUnited Kingdom Use the following
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 12BReference • 65 Reference Coaxial Cable Recommendations Caution: Careful selection of proper
66 • 12BReference XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Twisted-Pair Cable CAUTION: Careful selection of the proper cable is essenti
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 12BReference • 67 Network Cable Caution: Careful selection of proper cable is essential to obt
68 • 13BTechnical Information XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Technical Information with electronic control. Units available i
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 13BTechnical Information • 69 Real time clock allows scheduling of up to 64 events, including
70 • 13BTechnical Information XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Distance ft (m) Indoor Outdoor 24 V 28 VAC 24 VAC AC 28 VAC Wi
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 13BTechnical Information • 71 Table 5: Camera/Lens Specifications Model Numbers SVFT-C22, SVFT
For RS-422/485 Mode: ... 39 F
72 • 13BTechnical Information XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Model Numbers SVFT-C22CA, SVFT-P22CA, SVFT-W22CA/ SVFT-C22CA
XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 14BVicon Standard Equipment Warranty • 73 Vicon Standard Equipmeicon Industries Inc. (the “Comp
Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2
Introduction The information in this manual covers the installation, configuration and operation of the SurveyorVFT™ Camera Dome. This system should