Chapter 7: Configuration Parameters
Click Default to restore the default values for both thresholds.
Click Cancel to cancel this action and go back to the Threshold page in
Configuration Parameter window.
7.7 Redundant Controller Settings
This sub-window contains configuration options related to redundant
controller configurations. (See Figure 7-9) This Redundant page only
displays if your controller/subsystem comes with dual-redundant RAID
controllers.
Figure 7-9: The Redundant Page
Each option is executed by a two-step procedure. Click to select a desired
value from the pull-down menu, and then click Apply for the configuration
to take effect.
♦ Secondary Controller RS-232 Terminal: In a redundant controller
configuration, the RS-232C port on the Secondary controller is
normally nonfunctional. Enable this function if you wish to use the
port for debugging purposes.
NOTE:
Access to the Secondary controller only allows you to see controller
settings. In a redundant configuration, configuration changes have to be
made through the Primary controller.
♦ Periodic Cache Flush Time: If redundant controllers work with
Write-T
Back caching, it is necessary to synchronize the unfinished
writes in both controllers’ memory. Cache synchronization lets each
controller keep a replica of the unfinished writes on its partner, so
Redundant Controller Settings 7-11