Chapter 9: Drive Management
9.5. Physical Drive Maintenance
9.5.1 Read/Write Test
Figure 9-31: The Physical Drive Maintenance Window
Step1. To access the Read/Write Test maintenance option, select the
Physical Drives icon from the functional navigation panel on
the left of the RAIDWatch screen.
Step 2. Select a new drive from the Front View window. A used drive
(one that previously included in a logical configuration) can
also be tested with the precondition that its reserved space needs
to be manually removed.
Step 3. Select Read/Write Test from the tabbed menus in the
Functions window.
Step 4. Verify listed drive slot number. Select the Test type as either
Read-only or Read/Write test.
Step 5. There are two configurable parameters related to the
Read/Write test: Error Occurrence and Recovery Process.
Use the pull-down menu to configure a preferable test
condition. The configurable options are listed below:
Error Occurrence: This item specifies firmware’s reactions if
any errors should be found during the Read/Write test. Options
are: No Action, Abort on Any Error, Abort on Hardware Errors.
Note that the definitions of drive errors are determined by the
interface type. For SATA disk drives, errors are interpreted
according to SATA 8-bit error encoding.
Physical Drive Maintenance 9-29