2. Using the drilling guide as a template, mark the location of the four mounting holes [0.203 in.
(5.2 mm) diameter]. See Figure that follows.
Mounting Hole Pattern
3. There are two (2) cable access holes provided. Drill a hole in the wall or ceiling and route video
and power cables to the selected location and through one of the cable access holes. A 1/2-inch
connection (customer-supplied connector) is provided on the side of the base. A conduit or
electrical connector (screw-type) can be used in this threaded hole. The rear port is sized to
accept a 1/2-in. (customer-provided) connector. If it is desirable to use the rear cable access hole,
route the conduit through the hole; the supplied grommet can be used instead of the conduit.
Apply the provided sealant tape around the threads of the conduit pipe. See Figure above for hole
locations.
4. If using the rear cable access hole, insert the vent plug provided in the side cable access hole. If
the side cable access hole is used, insert a Street Tee (customer provided) into the cable access
hole. Route the conduit through the top hole and insert the vent plug provided into the bottom
hole. Refer to Figure that follows for installation options. Sealant tape is provided for the plug and
Street Tee. Insert the black plug provided into the rear cable access hole if the side access hole is
being used; if the rear cable access hole is being used, insert the provided plug into the side cable
access hole and tighten with tool provided.
Note: Failure to thoroughly coat threads will result in moisture entering the housing and eventual
failure of the unit.
Note: For outdoor installations, Vicon recommends that the vent plug should only be used if
fogging conditions exist. Additionally, if the side cable access hole is used, the base must be
mounted so the hole is pointed directly downward.